DAFC Auto.
Keep the drive.
Change the fuel.
A 10 kW-net-class direct-ammonia power system for a commercial L5 passenger three-wheeler. The OEM motor and inverter stay; ammonia supplies the primary energy.
Ammonia is the source.
The electric drive stays.
- NH₃ stored on board in a target 10 kg tank, subject to qualified storage and integration
- The DAFC and isolated DC/DC converter feed the vehicle DC bus
- A buffer battery in parallel handles acceleration and regenerative recovery
- Fuel is handled at a controlled depot, not public retail refuelling
Existing electric vehicle Source
H2ONE demonstrator Target
10 kW net means power delivered to the vehicle DC bus. The inverter, PMSM and drivetrain carry over from the reference vehicle.
Cruise demand is
not peak demand.
Modelled From the calibrated 791 kg GVW road-load model. No road test yet.
DC-bus power
- 30 km/h
- ≈1.74 kW
- 40 km/h
- ≈2.73 kW
- 55 km/h
- ≈4.89 kW
The rest of the 10 kW covers acceleration, gradients, payload, auxiliaries and a transient reserve.
Max sustained speed at 10 kW
- 0° grade
- 55 km/h
- 3° grade
- 47.5 km/h
- 6° grade
- 30.9 km/h
- 9° grade
- 22.3 km/h
- 12° grade
- 17.4 km/h
Steady-state equilibrium speeds; a power reference, not proof of sustained gradeability.
Vehicles that earn
while they move.
- High-utilisation passenger fleets
- Electric three-wheeler OEMs
- Controlled-depot fleet operators
Planned Target segments and customer hypotheses (charging downtime, uptime, repeat routes, operating cost) until fleet pilots demonstrate them. No OEM partner is signed.
Sealed, ventilated,
designed for occupants.
The ammonia system is contained, watched and isolated, with a predictable response to any fault. See how it works →
Contain. Detect.
Isolate. Purge.
The ammonia tank sits in a sealed enclosure under the driver's seat, kept at slightly lower pressure than its surroundings, so a leak is drawn away from the cabin. One protected line runs under the floor to the rear bay, where the fuel cell lives. Press play to see the designed response to a leak.
- NH₃ detectedEnclosure sensor reading rises
- WarningDashboard beacon and display
- Fuel supply isolatedValve at the vessel closes
- Stack current reducedLoad ramps down
- Enclosure purgedBlower boost, discharge downward
- Controlled shutdownCabin sensor stays clear
- Event loggedFleet operator notified
Planned Simulated, illustrative sequence, not a test result. Hardware interlocks are designed to act independently of software and connectivity. No vehicle-level safety test has been completed yet.
Sealed enclosure
Pressure-rated vessel with isolation valves, in an enclosure separated from the occupant space.
Ventilate and discharge
Negative-pressure ventilation and a controlled downward discharge, away from cabin openings.
What it watches
NH₃ at three points, ventilation, fuel pressure and flow, stack temperature, crash and tilt.
Depot first
Trained staff at a controlled depot, closed-connection couplings, leak checks before and after every fill.
From the measured cell
to a fleet pilot.
24 months. Funds the 900 cm²-class cell, the DAFC-10 stack and controls, ammonia-system validation and an L5 engineering vehicle. Equity terms are discussed privately.